Joerns DermaFloat APL Mattress System – Alternating Pressure Low Air Loss Mattress, 350 lb, 36″ or 42″ Wide
$4,067.00
- Rated No. 1 in customer service
- Fast nationwide shipping, delivered to your door
- Manufacturer warranties
- Cash-back rewards on every order
Authorized dealer & provider · Huge selection · Questions? Call 585-505-6665
✔ Alternating Pressure Plus Low Air Loss
✔ 20 Individual Air Cells
✔ 3 Cycle Times, 8 Comfort Settings
✔ Fowler Boost When the Head Is Raised
✔ CairRails Side Air Bolsters
✔ Rolls Up for Storage, 350 lb Capacity
-
Fast nationwide shipping, delivered to your door · 30-day returns on eligible products · Shipping & returns details
Share with Friends
- Description
- PRODUCT SPECIFICATION
- Shipping & Returns
- MANUAL/INSTRUCTIONS
- Reviews (0)
Description
Joerns DermaFloat APL Mattress System – Alternating Pressure with Low Air Loss, 350 lb
The Joerns DermaFloat APL is an alternating pressure low air loss mattress system. It alternates pressure between adjacent A and B air cells on a regular cycle to offload tissue and boost circulation, and it adds low air loss through an integrated air delivery system under the therapy pad.
Joerns built it for residents at risk of or being treated for pressure ulcers. Twenty cells redistribute weight, CairRails bolsters manage the edges, and Fowler Boost inflates the sacral section when the head of the bed is raised to 30 degrees or more. The mattress is lightweight and rolls up for storage. Capacity is 350 lb.
Choose 36″ x 80″ or 42″ x 80″ in the dropdown. Call 585-505-6665 with questions. We ship nationwide.
Why Choose the DermaFloat APL?
Alternating pressure is one of the most common therapies for pressure ulcers because it keeps changing which areas carry weight, which helps circulation reach the wound. The DermaFloat APL adds low air loss, up to 40 liters of airflow per minute when the cycle completes or in static mode, to help keep skin dry. Automatic panel lockout prevents unwanted changes, and an audible power failure alarm alerts staff.
Who Is the DermaFloat APL Best For?
It is a good fit for:
- Residents with Stage I to IV pressure ulcers (Joerns indications)
- Patients who benefit from cyclic offloading
- Burns, neurology, dermatology, amputations and rehabilitation
- Facilities that need a surface that rolls up for storage between residents
Who May Need Something Different?
- Residents over 350 lb: the DermaFloat LAL is rated to 500 lb and the Arise 1000 to 1,000 lb.
- Moisture is the main problem: the true low air loss DermaFloat LAL focuses on that.
- Mattress only: see the DermaFloat APL Mattress Replacement.
An Alternating Pressure Low Air Loss Mattress
The therapy cells automatically alternate between adjacent A and B cells. Joerns notes alternating pressure can aid healing by increasing circulation to the wound, and it pairs it with low air loss delivered beneath the therapy pad.
Twenty Cells and CairRails
Twenty individual cells distribute the resident’s weight evenly. CairRails side air bolsters add support at the edges.
Comfort and Cycle Controls
Three alternating cycle times and eight comfort control settings let the caregiver tune the surface, which Joerns says helps resident compliance and healing.
Fowler Boost
When the head of the bed is raised to 30 degrees or more, Fowler Boost inflates the sacral section to improve pressure redistribution where the resident’s weight shifts.
Safety and Convenience
Automatic panel lockout avoids accidental changes, an audible power failure alarm has a reset, and the lightweight mattress rolls up for portability and storage.
Choosing Your Options
Choose the size in the dropdown:
| Size | Item # |
| 36″ x 80″ | DFAPL3680NZ |
| 42″ x 80″ | DFAPL4280NZ |
Joerns lists the 36″ mattress at 36″ W x 80″ L x 8″ D.
DermaFloat APL vs. DermaFloat LAL
The APL alternates pressure with integrated low air loss and is rated to 350 lb. The LAL is true low air loss with pulsation, 10″ deep, rated to 500 lb. Pick the APL for cyclic offloading and the LAL when moisture management and higher weight are the priority.
Common Problem → DermaFloat APL Solution
Problem: a resident’s sacral wound worsens whenever the head of the bed is raised for meals.
Solution: Fowler Boost on the DermaFloat APL inflates the sacral section at 30 degrees and up, while alternating cells keep offloading.
Does it need to be set up for each resident? Set the comfort level and cycle time for the resident; panel lockout keeps those settings in place.
Size & Bed Fit
Pick 36″ or 42″ wide to match the bed deck, both 80″ long. The 36″ mattress is 8″ deep. Check that side rails still extend well above the surface.
Day-to-Day Use
Set the comfort level to the resident’s weight and comfort, choose a cycle time, then let panel lockout hold the settings. Raise the head of the bed as needed; Fowler Boost responds at 30 degrees and up. Check the resident’s skin at each turn, keep linens between the resident and the pad to a minimum so airflow can reach the skin, and keep the hose clear of the bed frame.
Care & Cleaning
Clean the therapy pad with facility disinfectants following Joerns instructions. The pad is fluid proof, moisture vapor permeable and treated with an antibacterial and antifungal agent. Inspect for tears and keep hoses free of kinks.
What’s Included
DermaFloat APL mattress with therapy pad and control unit.
Key Features
✔ Alternating Pressure Plus Low Air Loss
✔ 20 Individual Air Cells
✔ 3 Cycle Times, 8 Comfort Settings
✔ Fowler Boost When the Head Is Raised
✔ CairRails Side Air Bolsters
✔ Rolls Up for Storage, 350 lb Capacity
Product Specifications
| Brand | Joerns Healthcare |
| Model | DermaFloat APL Mattress System |
| Type | Alternating pressure with integrated low air loss |
| Weight Capacity | 350 lb |
| Sizes | 36″ x 80″ (8″ deep); 42″ x 80″ |
| Cells | 20 individual cells, A-B alternating |
| Airflow | Up to 40 liters per minute (cycle complete or static mode) |
| Controls | 3 alternating cycle times, 8 comfort settings, automatic panel lockout |
| Fowler Boost | Inflates sacral section at 30 degrees head elevation or more |
| Alarms | Audible power failure alarm with reset |
| Side Support | CairRails air bolsters |
Frequently Asked Questions
What is an alternating pressure low air loss mattress?
An air mattress that alternates which cells are inflated to shift pressure, while also moving air under the cover to keep skin dry.
What is the DermaFloat APL weight capacity?
350 lb.
What sizes are available?
36″ x 80″ and 42″ x 80″.
What is Fowler Boost?
It inflates the sacral section when the head of the bed is raised to 30 degrees or more.
Can the mattress be stored?
Yes, it is lightweight and rolls up.
Is there a power failure alarm?
Yes, an audible alarm with reset.
Do you ship nationwide?
Yes. Call 585-505-6665 with questions.
🔗 Hospital Bed & Mattress Guides
Choosing a pressure ulcer surface? Start here, or call us at 585-505-6665.
PRODUCT SPECIFICATION
| Mattress size: | 36″ W x 80″ L x 8″ D |
| Maximum weight capacity: | 350 lb |
| CPR quick deflation | |
| UL/CUL classified |
Shipping & Returns
Shipping & Return Policy
At MedCare Mobility, we understand that purchasing medical and mobility equipment is an important decision. Our goal is to make the ordering, delivery, and return process as clear and straightforward as possible.
Because many of the products we offer are large, specialized, or shipped directly from manufacturer and distributor warehouses, shipping and return requirements may vary somewhat by product and brand. The policy below explains what you can generally expect when ordering from MedCare Mobility.
Shipping & Order Processing
We ship medical and mobility equipment to customers throughout the United States. Orders are processed as quickly as possible, and tracking information is provided once available.
Processing Time
Most in-stock orders are processed within approximately 1–3 business days. Processing may include order verification, warehouse preparation, packaging, and coordination with the manufacturer or distributor.
Some specialty equipment, made-to-order products, oversized items, or products shipping directly from a manufacturer may require additional processing time. Any estimated processing or lead time shown on an individual product page should be considered part of the expected fulfillment timeframe for that item.
Transit & Delivery Time
Once shipped, many standard orders arrive within approximately 3–7 business days. Larger medical equipment, freight shipments, specialty products, and certain manufacturer-direct orders may require additional transit time.
Tracking information will generally be emailed once the shipment has been processed by the carrier. If you have questions regarding the status of your order, please contact us at info@medcaremobility.com.
Alaska, Hawaii & Special Shipping Areas
Orders shipping to Alaska, Hawaii, and certain remote or limited-access areas may be subject to additional shipping charges. If an additional charge is required after your order is reviewed, we will contact you before proceeding whenever additional payment is necessary.
Freight & Oversized Equipment
Hospital beds, patient lifts, large recliners, ramps, and other oversized medical equipment may ship by freight rather than standard parcel service. Unless a specific delivery service is stated on the product page or order, freight delivery does not automatically include inside delivery, assembly, installation, or removal of packaging.
Please note: Shipping costs for homecare and long-term care beds delivered to a residence may vary, and liftgate service may be required. Call us for an exact quote. If the shipping cost differs from what was shown at checkout, we’ll contact you after you place your order.
30-Day Return Policy
We want you to feel comfortable ordering from MedCare Mobility. Most eligible products may be returned when a return is requested within 30 days of delivery, subject to the conditions and exclusions outlined below.
Eligible products generally include:
- Electric and power wheelchairs
- Manual and lightweight wheelchairs
- Mobility scooters
- Walkers and rollators
- Patient lifts
- Wheelchair ramps
- Hospital and homecare beds
- Eligible medical mattresses
- Geriatric and medical recliner chairs
- Overbed tables
- Bathroom benches and shower chairs
- Other eligible medical and mobility equipment
Return eligibility can vary by manufacturer and product type. Products specifically identified as non-returnable, custom, made-to-order, or otherwise subject to special return terms are governed by those terms.
Return Authorization
Please contact us before shipping any product back. Returns must first be approved and issued a Return Authorization (RA) and the appropriate return shipping address.
You may request a return by emailing info@medcaremobility.com or contacting our customer service team through the live chat on our website.
Please do not return merchandise to an address shown on the original shipping label unless specifically instructed to do so. Many products ship directly from manufacturer or distributor warehouses, and the correct return location may be different from the original shipping location.
Condition of Returned Merchandise
To qualify for a return and refund, the product must be returned:
- In brand-new and unused condition
- In its complete original manufacturer packaging
- With all manuals, components, hardware, accessories, and included materials
- Without damage, modification, assembly wear, stains, odors, or other signs of use
- In resalable condition upon inspection by the receiving warehouse or manufacturer
We strongly recommend keeping the original box, pallet, protective materials, and packaging until you are certain that you intend to keep the equipment. Large medical equipment can be difficult or impossible to return safely without its original packaging.
Restocking Fees
Approved returns are subject to a mandatory restocking fee, generally ranging from 15% to 20% of the applicable product price. The exact restocking percentage varies depending on the manufacturer, brand, and type of equipment being returned.
These restocking charges are assessed to us by the manufacturer or distributing warehouse when merchandise is returned. MedCare Mobility does not add the fee simply as a return penalty; when the manufacturer requires the charge, we must pass the applicable amount through as part of processing the return.
If you would like to know the applicable restocking percentage for a particular product before ordering, please contact us and we will be happy to help whenever that information is available from the manufacturer.
Return Shipping & Shipping Charges
The customer is responsible for shipping charges associated with the order when making a standard return.
Customers are responsible for arranging for the approved merchandise to be returned to the return address provided with the Return Authorization. In certain cases, we may be able to provide a prepaid return label or coordinate return transportation for your convenience. When provided, the applicable shipping cost may be deducted from the final refund.
Because some medical equipment is oversized or requires freight transportation, prepaid labels or carrier call tags may not be available for every product. Our customer service team will provide the available return instructions when your return is authorized.
Non-Returnable Products
For health, hygiene, safety, customization, and manufacturer-policy reasons, certain products are not eligible for standard returns.
We currently do not accept returns on:
- Parts & accessories
- Wheelchair cushions and support accessories
- Patient lift slings
- Custom or made-to-order products
- Products specifically identified as non-returnable on the product page
If a non-returnable product arrives damaged, defective, or incorrect, please contact us promptly. Non-returnable status does not prevent us from assisting with a legitimate shipping damage, defect, warranty, or fulfillment issue in accordance with the applicable manufacturer and carrier procedures.
Damaged or Incorrect Orders
We take shipping damage seriously and will work with you to help resolve legitimate delivery issues.
If your product arrives damaged, please notify MedCare Mobility within 48 hours of delivery. Whenever possible, retain the shipping carton, pallet, packaging materials, and the product exactly as received and take clear photographs of the packaging and any visible damage.
Reporting damage promptly is important because carriers and manufacturers have limited timeframes for filing freight and shipping claims.
If you receive an incorrect product or believe there is a manufacturer defect, please contact us before returning or disposing of any merchandise or packaging so that we can provide the appropriate instructions.
Refused Deliveries
Please contact us before refusing a delivery unless the shipment has obvious significant freight damage and the carrier is documenting the damage at delivery.
A shipment that is refused for reasons unrelated to verified shipping damage may be treated as a standard return. Applicable restocking and shipping charges may therefore be deducted from the refund.
Return Shipping Deadline
Once a return has been approved and return instructions or a return label have been issued, the merchandise must be shipped within 72 hours unless MedCare Mobility provides different instructions in writing.
This is particularly important when a return is approaching the end of the applicable return period. Returns shipped outside the authorized timeframe may be refused by the manufacturer or warehouse and may no longer qualify for a refund.
Refund Processing
Refunds are processed after the returned merchandise has been received and inspected by the applicable warehouse or manufacturer and the return has been confirmed to meet the return requirements.
The applicable restocking fee, shipping charges associated with the order, and any other authorized return-related charges will be deducted from the amount eligible for refund.
If returned merchandise is used, damaged, incomplete, missing original packaging or components, or otherwise returned in a condition that prevents the manufacturer or warehouse from accepting it as new and resalable merchandise, the return may be refused or the refund may be reduced in accordance with the manufacturer\’s assessment.
Custom & Made-to-Order Products
Products identified as custom, configured, made-to-order, special-order, or manufactured specifically for the customer cannot generally be canceled once production or manufacturer processing has begun and are not eligible for standard returns.
For custom products, cancellation may only be possible during the initial processing period and before production or customization begins. Because production schedules vary by manufacturer, we encourage customers to contact us immediately if a change is required.
If a custom product arrives damaged or has a legitimate manufacturing defect, we will work with the manufacturer to pursue the appropriate resolution, replacement components, repair, or other available remedy under the applicable manufacturer policy or warranty.
Questions Before Ordering?
Medical equipment can vary considerably in size, configuration, compatibility, and intended use. If you are unsure whether a product will work for your needs, we strongly encourage you to contact us before placing your order.
Our team is happy to help review product specifications, dimensions, options, compatibility, and available manufacturer information so you can make a more informed purchasing decision and reduce the possibility of needing a return.
For shipping, return, or product questions, contact us at info@medcaremobility.com or speak with us through the live chat on our website.
-Optional Add OnsOptional accessories for the Joerns DermaFloat APL Mattress System — add any to your order
See all accessories →
Joerns DermaFloat APL Mattress Replacement – Alternating Pressure Low Air Loss Mattress, 20 Cells, 8″ Deep, 36″ or 42″ x 80″, 350 lb
$1,718.00
New arrivals

Reviews
There are no reviews yet